PA612
+
  • PA612

Product Characteristics:
Compared with PA610, PA612 has low water absorption and good dimensional stability 


Main Use:
toothbrush bristle, monofilament, cable coating, etc.


Product Parameters

Basic Information

Numerical (Dry State/Wet State)

Unit

Test Method

Resin identification

PA

-

ISO 1043

Identification code

>PA<

-

ISO 11469

Physical properties

Numerical

Unit

Test method

Density

1050

kg/m3

ISO 1183

Melting point 

205-215

oC

--

Drying loss

≤1.0

Please translate the following text into English: ‰

--

Granularity

40-60

N/g

--

Mechanical properties

Numerical

Unit

Test method

Tensile strength

≥55

KJ/M2

ISO 527-1/-2

Bending strength

≥50

MPa

ISO 178

Tear elongation

≥150

%

ISO 527-1/-2

Bending strength of simply supported beams without notch impact

25JNB

kJ/m2

ISO 179/1eU

Injection molding*

Numerical

Unit

Test method

Resin drying (dehumidification drying)

 

 

 

Temperature

80

oC

-

Time

6-8

h

-

Water content

≤0.10

%

-

Melt temperature

240-260

oC

-

Mold temperature

80-100

oC

-

*It is recommended to use personal protective equipment during the injection molding process. The processing area should be well ventilated. It is recommended to clean the screw with high-density polyethylene (HDPE) before and after injection molding.